Impact and Environmental Recorders Product Specifications
ShockLog Product Specifications
| Operating Temperature Range |
Standard -4°F / -20°C to 158°F / 70°C
Extended -40°F / -40°C to 185°F / 85°C |
| Size |
7.1" x 3.3" x 1.7" |
| Weight |
1.5lbs (without battery) |
| Battery |
1 x 3.6V lithium size C
1 x 1.5V alkaline size C |
| Case Material |
Aluminum IP67 rating |
| Scale Factor Accuracy at 5G |
+ / - 2% |
| Acceleration Range |
+ / - 0.001 to + / -100G |
| Cut-Off Frequency Options |
10Hz, 50Hz, 90Hz, 250Hz |
| Wake-Up Threshold (% of Range) |
5–95% |
| Warning and Alarm Threshold (% of Range) |
6–95% |
| Wake-Up Time |
1.5ms |
| External Power Source Option |
4.8V min / 18V max |
Micro ShockLog Product Specifications
| Operating Temperature Range |
- 40°F / -40°C to 185°F / 85°C |
| Size |
3.3" x 3.3" x 2.0" |
| Weight |
0.7lbs (without battery) |
| Battery |
1 x 3.6V lithium size AA
1 x 1.5V alkaline size AA |
| Case Material |
Aluminum and steel — IP67 rating with connector and cap fitted |
| Operating Range Options |
10G and 100G |
| Wake-Up Threshold (% of Range) |
10–95% |
| Alarm Threshold (% of Range) |
11–95% |
| Wake-Up Time |
1.5ms |
Accessories
eTrack™
| Operating Temperature Range |
-40°C to 85°C |
| Size |
6.3" / 160mm x 9.8" / 250mm x 1.6" / 40mm |
| Weight |
1.53lbs / 696g |
| Power Supply |
Solar panel, trickle charge to 680mA hour LiOn battery |
| Case Material |
ABS |
| Regions |
Global provided GSM network coverage available |
Tilt & Roll Accelerometer Specifications
| Operating Temperature Range |
Standard -40 to 85°C |
| Size |
3.3" / 84mm x 3.3" / 84mm x 1.9" / 47mm |
| Weight |
0.7lbs / 317.51g (without battery) |
| Battery |
2 x 3.6V Lithium Thionyl Chloride |
| Case Material |
Aluminium, IP67 Rating |
| Tilt Range Monitored |
+/-90° |
| Resolution |
0.3° |
| Transverse Sensitivity |
5% |
| Noise (rms) |
DC-30 |
External Temperature, Humidity, and Pressure Sensor Specifications
| Temperature Measuring Range |
-40°F/-40°C to 185°F/85°C |
| Humidity Measuring Range |
0-100% RH |
| Pressure Measuring Range |
0–1.1 bar (standard) |
Contact us
For additional information and questions on any of our damage prevention
products, please
contact us.