FleetControl Manager Specifications
| Operating Temperature | -4°F/-20°C to +140°F/+60°C |
|---|---|
| Operating Humidity | 0-100% noncondensing |
| Impact Detection Range | User-adjustable threshold 0G to 10G |
| Output Alarm | Piezoelectric 98dB |
| Case Size | Main unit: 3.36" x 5.50" x 1.45" |
| Case Material | Main unit: PC/ABS |
| Case Rating | NEMA 4X |
| Power Source | Powered USB or powered com-port |
| Relay Output | Normally open contact fused @ 5 amps
Normally closed contact fused @ 10 amps |
| Data Storage Capacity | 1,300 events (operator log on/off) (impact time/date)
1,000 authorized operators |
| VMC Hardware/SW Requirements | Free USB 1.0 or higher port or free power com-port
Windows® XP 70mg tier disk space on hard drive |
| Inputs | 4 Digital: max voltage 64VDC
Modes: change of state, counter, timer, interrupt High transition voltage <= 7VDC Low transition voltage >= 2VDC Minimum hysterisis: 0.8 V - battery 1 external voltage 3 Analog: max voltage 64VDC Modes: high/low levels, change of state, counter, timer Full scale approximately 64VDC 10-bit resolution |
For additional information or questions about any of our damage prevention products, please contact us.