EquipManager® Product Specifications
| Operating Temperature |
-4°F/-20°C to +140°F/+60°C
(optional heater available for cold room applications) |
| Operating Humidity |
0–100% noncondensing |
| Impact Detection Range |
User-adjustable threshold 0.3G to 7G |
| Operating Shock |
10G (nondestructive)/100G (destructive) |
| Output Alarm |
Piezoelectric 98 dB |
| Case Size |
Main Unit: 4.33" x 4.33" x 2.8"
Control Head: 6.25" x 3.5" x 2.75" |
| Case Material |
Main Unit: Polystyrene
Control Head: Polycarbonate |
| Case Rating |
NEMA 4X |
| Power Source |
10 to 60 VDC |
| Relay Output |
Normally open contact fused @ 5 amps
Normally closed contact fused @ 10 amps |
| Data Storage Capacity |
1300 events (operator log on/off) (impact time/date)
1000 authorized operators |
| Data Retrieval |
8K x 8 memory device and/or RF data transmission |
| Radio Specifications |
802.11 WiFi:
IEEE 802.11b/g Direct Sequence Compliance Protocol
FCC Part 15 Class B, ETS 300.339
Compliance Bandwidth: 2.4 to 2.5GHz
Receiver Sensitivity: -81 dB
900MHz:
Power Output: 1 mW - 1 Watt (0 - 30 dBm)
RF Data Rate: 9.6 or 115.2 Kbps
Interface Data Rate: up to 230.4 Kbps
Receiver Sensitivity: -110 dBm (@ 9600 bps)
Spread Spectrum Type: FHSS (Frequency Hopping
Spread Spectrum)
Channel Capacity: 10 hop sequences share
50 frequencies
Encryption: 256-bit AES
Frequency Band: 902 - 928MHz
Certifications:
United States (FCC): OUR-9XTEND
Canada (IC): 4214A-9XTEND
Australia: Approved (XTH9)
Class 1 Division 2: Approved |
| Inputs |
8 Digital:
max voltage 64 VD
Modes: change of state, counter, timer, interrupt
High Transition Voltage <= 7 VDC
Low Transition Voltage >= 2 VDC
Minimum Hysterisis: 0.8 V
2 Analog:
max voltage 64 VDC
Modes: high/low levels, change of state, counter, timer
Full scale approximately 64 VDC
10-bit resolution |
| Control Head Display |
2 X 20 transmissive, green LED, black/white LCD
5 X 8 character format |
|